home *** CD-ROM | disk | FTP | other *** search
/ NetNews Offline 2 / NetNews Offline Volume 2.iso / news / comp / dcom / modems-part1 / 323 < prev    next >
Encoding:
Text File  |  1996-08-05  |  2.0 KB  |  56 lines

  1. Newsgroups: comp.dcom.modems
  2. Path: lazrus.cca.rockwell.com!dtmedin
  3. From: dtmedin@cca.rockwell.com (David T. Medin)
  4. Subject: Re: Sportster 28800 Vi at 57600
  5. X-Nntp-Posting-Host: marley.cca.rockwell.com
  6. Message-ID: <DKMt14.D20@lazrus.cca.rockwell.com>
  7. Originator: dtmedin@marley.cca.rockwell.com
  8. Sender: news@lazrus.cca.rockwell.com
  9. Organization: Rockwell Avionics - Collins, Cedar Rapids, IA
  10. References: <4cd3m5$1a2@news2.aimnet.com> <4cda93$71h@kryten.awinc.com>
  11. Date: Thu, 4 Jan 1996 00:51:03 GMT
  12.  
  13.  
  14. In article <4cda93$71h@kryten.awinc.com>, jcass@awinc.com (jcass) writes:
  15. > JNavas@NavasGrp.com (John Navas) wrote:
  16. > >Some articles posted here have suggested that the Sportster 28800 Vi does
  17. > >not work reliably at 57600 (and that USR has "admitted" it).  For the
  18. > >record, I have not seen such a problem in dozens of hours of both testing
  19. > >and actual use.  For example:
  20.  
  21. [test results deleted]
  22.  
  23. > John, the problem seems to be primarily or entirely related to voice
  24. > mail.  I was able to connect and transfer at 57.6 and 115.2 before I
  25. > discovered the 38.4 fix; however getting the modem to initilize and
  26. > dial out or answer an incoming call at the higher rates was quite
  27. > another matter--it was a struggle to say the least.  Now everything
  28. > seems fine at 38.4.
  29.  
  30. The symptoms I see are as follows:
  31.  
  32. Serial Line
  33. Rate          FAX/data              Voicemail
  34.  
  35. 38K         Works great, but       Works great
  36.              too slow for 28.8
  37.              with v.42/bis
  38.  
  39. 57K          Will accept AT         Doesn't work
  40.              command 1 out of 3
  41.              times and will not
  42.              establish a connection
  43.  
  44. 115K         Works great            Flaky as heck
  45.  
  46. This is over a sample of four modems. All show the above behavior,
  47. have the 8/8/95 supervisor code, and were all purchased around the
  48. same time in November.
  49.  
  50. -- 
  51. -------------------------------------------------------------------
  52.        David Medin            Phone: (319) 395-1862
  53.    Rockwell Collins ATD          Internet:
  54.      Cedar Rapids, IA           dtmedin@cca.rockwell.com
  55.